Anaesthesia Machine in Hospital (Glory Plus)

  • Model NO.:Glory Plus

  • Kind:Anaesthesia Machine

  • Group:All People

  • Source:Oxygen

  • Type of Operating Light:All People

  • Weight:86kg

  • Workibg Temperature:+10~+40 Oc

  • Main Power:100-240V AC, 50/60Hz

  • Working Mode:Closed, Semi-Closed, Semi-Open

  • Safety Value:<=8kpa

  • Specification:CE, ISO

  • HS Code:90189070

  • Type:Anaesthesia

  • Certification:CE, FDA

  • LCD Display:With LCD Display

  • Anesthesia:Closed, Semi-Closed, Semi-Open

  • Dimensions(H X W X D):1385mm×830mm×630mm

  • Storage Temperature:-20~+55 Oc

  • Storage Humidity:<=93%

  • Battery(Option):24V DC Minimum 120 Min

  • Operating Mode:Man./Vent

  • Trademark:everich

  • Origin:China

Product Description

Aeon Glory Plus Anesthesia Machine
CE marked, meets both EU and domestic clinical sefety requirement
Large LCD screen,Various monitoring waveform and parameters in different colors
IPPV,Pressure mode, SiMV modes can easily satisfythe operation ventilation requirement
Integrated CO2 absorption systerm equipped with NO WATER VAPOR COAGULATION  sensor and fast-release APL value
6-tube of flow meters for three gas sources satisfy long operation requirement
Optional AGSS provides more protection
Technical Speciication

Dimensions(H x W x D)1385mm×830mm×630mm
Weight86kg
Storage temperature-20~+55ºC
Workibg temperature +10~+40ºC
Storage humidity≤93%
Main power100-240V AC, 50/60Hz
Battery(option)24V DC, minimum 120 min
Working modeClosed, Semi-closed, Semi-open
Deiven modePneumatically driven and electronically controlled
Operating modeMan./ Vent.
Safety value≤8kpa
Patient typeAdult, pediatric
Ventilation mode IPPV, PLV, SIMV,PS and Manual
Tidal volume50-1600ml
Ventilator frequency4-100bpm


Physical & Environmental Specification
Dimensions(H x W x D): 1385mm×830mm×630mm
Weight: 86kg
Storage temperature: -20~+55ºC
Workibg temperature: +10~+40ºC
Storage humidity: ≤93%

Electrical Specification:
Main power: 110-240V AC, 50/60Hz
Battery(option): 24V DC, minimum 120 min

Pneumatic Specification:
Working mode: Closed, Semi-closed, Semi-open
Deiven mode: Pneumatically driven and electronically controlled
Operating mode: Man./ Vent.
Safety value: ≤8kpa

Ventilator Specification:
Patient type: Adult, pediatric
Ventilation mode: IPPV, PLV, SIMV PS, Manual
Setting: Touch key & navigator wheel knob
Tidal volume: 50-1600ml
Ventilator frequency: 4-100bpm
I:E ratio: 2:1-1:8
Alarm: High Airway Pressure/Low Airway Pressure
             High Minute Volume/Low Minute Pressure
             High Breath Rate/Low Breath Rate
             High FiO2/Low FiO2
             O2 Supply failure
             Circle Mistake
              Power failure