Product Category
Contact Person
Model NO.:N-117M
Type:Biological
Mobility:76-50mm
Shape:Single-lens
Principle:Electronic
Achromatic Objective:4×,10×,40×,100×
Focusing Moving Range:24mm
Specification:CE, ISO
HS Code:90118000
Magnification:40-1600X
Number of Cylinder:Monocular
Kind of Light Source:Electronic
Usage:Teaching and Resarch
Viewing Head Interpupilary Distance:48-75mm
Double Layer Mechanical Stage:132×142mm/ 75×40mm
Trademark:everich
Origin:China
Product Description
I,Safety note
1. Carefully open the box, avoid the accessories, like lens, dropping to ground and being damaged.
2. Do keep the instrument out of direct sunlight, high temperature or humidity, dusty and easy shaking environment. Make sure the stage is smooth, horizontal and firm enough.
3. When moving the instrument, please use two hands to grip with the two sides of the microscope body.
4. When running, the lamp house and nearby parts will be very hot. Please ensure there is enough cooling room for them.
5. Make sure the instrument is earthed, to avoid lighting strike.
6. For safety, be sure the main switch is in "O"(off) state before replace the halogen (LED) lamp or the fuse, then cut off the power, and do the operation after the lamp bulb and the lamp house completely cool.( specified lamp: Halogen Lamp 6V/20W or LED lamp 3W)
7. Check the input voltage: be sure the input voltage which signed in the back of the microscope is consistent with the power supply voltage, or it will bring a serious damage to the instrument.
8. Use the factory supplied power cord, please.
II,Maintenance
1. All the lenses have been well checked and adjusted. It is forbidden to disassemble them yourself.
2. The nosepiece and coarse/fine focus unit have a compact and precise frame, please don't disassemble them as possible as you can.
3. Keep the instrument clean, wipe dust regularly, and be attention to avoid contaminating the optical elements especially.
4. The contaminations on the prism, as finger mark and oil, could be gently wiped with a piece of soft cloth or tissue paper, gauze which has been immersed in pure alcohol or xylene. (note that the alcohol and the xylene are all burned easily, do not let them near the fire, and use them in a drafty room as possible as you can.)
5. Don't use organic solvent to wipe the non-optical elements, when you need to clean, use the soft detergent, please.
6. When using, if the microscope is splash by liquid, cut off the power at once, and wipe up the moisture.
7. Do not disassemble any parts of the microscope. That will affect the function or decline the performance of the microscope.
1. Place the instrument in a cool, dry position. After using the microscope, remember to cover it with dust helmet. Do wait for the lamp house cooling completely before cover.
Specification:
| N-117M | ||
| Viewing Head | Compensation Free Binocular Head, Inclined at 30°, Interpupilary Distance 48-75mm | Δ |
| Compensation Free Trinocular Head, Inclined at 30°, Interpupilary Distance 55-75mm | √ | |
| Eyepiece | WF10×/18 | Δ |
| P16×/11 | √ | |
| Objective | Achromatic Objective 4×,10×,40×,100× | Δ |
| Nosepiece | Backward Quadruple Nosepiece | Δ |
| Stage | Double Layer Mechanical Stage 132×142mm/ 75×40mm | Δ |
| Focusing | Coaxial Coarse & Fine Adjustment, Moving Range 24mm, Fine Division 0.004mm | Δ |
| Condenser | Abbe NA 1.20 with Iris Diaphram & Filter | Δ |
| Abbe NA 1.25 with Iris Diaphram & Filter | √ | |
| Illumination | S-LED, Brightness Adjustable | Δ |
| Halogen Lamp 6V/ 20W, Brightness Adjustable | √ | |
| Phase Contrast Kit | √ | |
| Dark Field Attachment | √ | |
| Polarization Attachment | √ | |
Note:Standard Outfit Δ, Optional √