Infusion Pump in Hospital (Model: ZNB-XB-Y1200)

  • Model NO.:ZNB-XB-Y1200

  • Certification:CE, ISO13485

  • LCD Display:With LCD Display

  • Ordinary Infusion Apparatus:0.1ml/H-600ml/H

  • Low Speed(1ml/H):250~500 Seconds

  • Power Supply: a C:220V±22V; 50Hz±1Hz

  • Built-in Battery Work Time:30va

  • Product Dimension:185×115×196(Mm)

  • Specification:CE, ISO

  • HS Code:90189090

  • Type:Infusion Pump

  • Group:All People

  • Specialized Infusion Apparatus:0.1ml/H-1200ml/H

  • Remarks:with 0.1-30ml/H (0.1ml/Step); Over 30ml/(1ml/Step

  • Medium Speed (120ml/H):7~14 Seconds

  • Power Consumption:30va

  • Relative Humidity:20%-90%

  • Trademark:everich

  • Origin:China

Product Description

Technical parameters: 

Power supplyA C: 220V±22V; 50Hz±1Hz;

             D C: 12V (built-in battery)
FuseF0.75AL(socket back), T1A (switching power supply L.N)
Power consumption30VA
Built-in battery work time30VA
Environmental temperature+5ºC-+40ºC
Relative humidity20%-90%
Product dimension185×115×196(mm)
weight3.8kg
Low speed(1ml/h)250~500 seconds


Infusion flow rate
Specialized infusion apparatus:0.1ml/h-1200ml/h;
Ordinary infusion apparatus:0.1ml/h-600ml/h; 
Remarks: with 0.1-30ml/h (0.1ml/step); over 30ml/(1ml/step).
Infusion accuracy error
Specialized infusion apparatus:±5%(medium speed, 23ºC, humidity: 60%);
Specialized infusion apparatus:±5%(medium speed, 23ºC, humidity: 60%);
Total infusion volume preset: 0.1-9999ml.
Remarks: with 0.1-30ml/h (0.1ml/step); over 30ml/(1ml/step).
Occlusion sensitivity: It has three adjustable levels of occlusion pressure as high, medium and low.
Low speed(1ml/h):250~500 seconds;
Medium speed (120ml/h):7~14 seconds;
Above data is measured at the status of 25ºC ambient temperature, ordinary pressure, use ordinary PVC(∮3)infusion apparatus and high sensitivity.
KV0: 1-2ml/h.
Power supply:
A C: 220V±22V; 50Hz±1Hz;
D C: 12V (built-in battery).
Fuse: F0.75AL(socket back), T1A (switching power supply L.N).
Power consumption: 30VA.
Built-in battery work time: 30VA.
Under the sufficient battery, medium speed flow rate, the battery can continuous work about 2 hours after power is switched off. Run time is related to flow rate. Within the battery normal life, the run time should not be less than 2 hours. The battery could charge and discharge about 400 times. 
working condition:
Environmental temperature:+5ºC-+40ºC; 
Relative humidity: 20%-90%;
Product dimension and weight:185×115×196(mm), 3.8kg. 
security classification: