LCD Laptop Pulse Oximeter with Battery (PM-600B)

  • Model NO.:PM-600B

  • Type:Pulse Oximeter

  • Group:Adult, Pediatric, Infant, and Neonate

  • Transportation and Storage:20°c~60°c

  • Mode:Audible and Visible Alarm

  • Operation Time:7 Hour

  • LED Indicator:Red and Green Dual Colour LED

  • Green LED:Indicate Pulsating Rhythm

  • Specification:CE, ISO

  • HS Code:90181930

  • Classification:Imaging Diagnostic Equipment

  • Certification:CE

  • Temperature Operation:0 ~ 45 °c

  • Measurement Range:30 ~ 250bpm

  • Setup:User-Adjustable High and Low Limits

  • Screen:128×64 Monochrome LCD

  • Red LED:Indicate Insufficient Battery Capacity

  • Trademark:everich

  • Origin:China

Product Description

Features:  
        Standard configuration of  SPO2, PR and PLETH
           2.8 inch color LCD for real time display SpO2 waveform and PR strength
           Long time monitoring and sleeping monitoring
           Audible and visual alarm when parameters exceeded and/or sensor-off
           AA alkaline battery to support continuous 6 hour operation timeO
           Indicator for battery capacity with related prompt in case of low battery capacity
           Automatic power off in case no operation within the preset time duration
           Optionalconfiguration of TEMP and AC power
Specifications:


Patient Range    


Adult, pediatric, infant, and neonate    


Oxygen saturation (SPO2)    


Measurement range: 35%~100%
Accuracy: ±2%(70%~100%),0%~69%(unspecified)
Resolution:1%    


 
Pulse Rate    


Measurement range: 30bpm~250bpm
Accuracy: ±2bpm
Resolution: 1bpm    


TEMP    


Channel: 1
Input: Body surface temperature sensor featuring thermal-sensitive resistor
Measurement range:0ºC~50ºC
Accuracy: 0.2ºC
Resolution:0.1ºC    


 
Display Mode    


LCD screen:128×64 monochrome LCD to display information for all parameters
LED indicator: Red and green dual colour LED
Red LED: Indicate insufficient battery capacity
Green LED: Indicate pulsating rhythm    


 
Storage and Recall    


36 hour trend data for SPO2/PR/TENP data with corresponding date and time    


 
Alarm    


Mode: Audible and visible alarm
Setup: User-adjustable high and low limits    


 
Operation Environment    


Temperature
Operation: 0ºC~45ºC
Transportation and storage:20ºC~60ºC

Humidity
Operation: 15%~95% (non-condensing)

Altitude
Operation: 86kPa~106kPa
Transportation and storage: 50kPa~106kPa    


 
Power Requirements    


Battery: Common1.5VAA alkaline or rechargeable battery
Operation time: 7 hour    


 
Selectable Sensor    


Adult finger Spo2 sensor
Neonate/infant wrap Spo2 sensor