Mhj-IC Versatile Anesthesia Machine (model MHJ-IC)

  • Model NO.:MHJ-IC

  • Certification:CE, ISO13485

  • LCD Display:With LCD Display

  • Anesthesia:Semi Open Suction

  • Flow:O2 0.05~1L/Min; 1~10L/Min

  • Air:0.2~12L/Min

  • O2 Flush:20-75L/Min

  • Zfg-B1 Output Concentration:0-5vol% with T.P.F.Compensations

  • CO2 Absorber Volume:≥1.6L

  • Trademark:everich

  • Origin:China

  • Type:Anaesthesia

  • Group:Adult and Children

  • Source:Air,Nitrous,Oxygen

  • Type of Operating Light:Without

  • N2o:0.05~1L/Min; 1~10L/Min

  • Orc:O2≥ 25%

  • Draeger LC Output Concentration:0.2%-6%

  • Relief Valve:0-7kpa

  • Leakage:≤175ml/Min

  • Specification:CE, ISO

  • HS Code:90189070

Product Description

MHJ-IC is a new generation anesthesia machine incorporating anesthesia, respiratory and monitoring functions. ANESTHESIA MACHINE:
It adopts a two-stage pressure regulator and a high precision dual-tube flowmeter to provide an accurate fresh gas output. Its build-in safety devices such as ORC system, oxygen deficiency alarm and N2O cut-off make anesthesia more safe. The specially constructed inter-lock mechanism may guarantee only one of the two parallel vaporizers to be switched on at a time., The selected vaporizers from world famous companies as Drager 19.3, Ohmeda TEC-5 and Penlon Sigma Delta satisfy different requirements of customers.
With MHJ-IC it is possible to act low-flow anesthesia because of its unique integrated circle system- a system that keeps the inhaled tidal volume from fresh gas. So it not only saves anesthesia agent but also reduces pollution to operation room.


Specification

Gas supply O2/N2O/AIR: 0.27-0.55MPa
Flow adjustment O2/N2O :0.05-10L/min

             Air:0.2-12L/min
Flow adjustmentO2+N2O or O2+Air
O2 flush 20-75L/min
VaporizerDraeger LC output concentration 0.2%-6%
MonitoringExhaled tidal volume, Minute volume, airway pressure, ventilation frequency, Inspired oxygen concentration.
Alarm Visual and Audible alarm for O2 supply low, Paw low, Paw high, MV low, MV high, Apnea, O2%low, O2%high, battery low, batter insufficient Power failure.


Gas supply:         O2/N2O/AIR: 0.27-0.55MPa
Flow adjustment: O2/N2O :0.05-10L/min
                                      Air:0.2-12L/min
Flow adjustment :O2+N2O or O2+Air
O2 flush:                20-75L/min
Build-in Safety device
               Oxygen ratio control(ORC)guarantee minimum 25% concentration of oxygen
              Oxygen deficiency alarm when O2≤0.2Mpa,audible alarm occurs and lasts 7 seconds
              N2O cut-off when O2≤0.1Mpa,N2O cut-off is activated
Backup power when AC power fails,the power switch over to internal battery which will run the machine for approximately four hours
Vaporizer:
 Draeger LC output concentration 0.2%-6%
 ZFG-B1 output concentration:0-5VOL% with T.P.F.compensations
 Anaesthesia circuit:
       Relief valve:0-7kPa
       CO2 absorber volume:≥1.6L
       Leakage:≤175mL/min
Anaesthesia ventilator:
       Ventilation Modes:Manual,Spontaneous,Mechanical CMV, etc.
       I:E ratio 1:9.9-1:9.9(Reversed 1:E optional)
       Ventilation Frequency:4-65bmp
       Tidal Volume: 20-1500ml(optional)
       PEEP:0-2kPa
Monitoring:Exhaled tidal volume, Minute volume, airway pressure, ventilation frequency, Inspired oxygen concentration.
Alarm: Visual and Audible alarm for O2 supply low, Paw low, Paw high, MV low, MV high, Apnea, O2%low, O2%high, battery low, batter insufficient Power failure.