S1100 Ventilator in Hospital (model: S1100)

  • Model NO.:S1100

  • Certification:CE, ISO13485

  • LCD Display:With LCD Display

  • Two Driven Mode:Electric and Pneumatical

  • Gas Source:O2

  • Voltage:~220V+/-22V

  • Pressure Safety Relief Valve:<125CMH2o

  • Max Safety Pressure:<12.5kpa

  • Trademark:everich

  • Origin:China

  • Type:Ventilator

  • Group:Adult

  • Source:Oxygen

  • Display Screen:TFT LCD

  • Rated Working Pressure:280kpa~600kpa

  • Frequency:50Hz+/-1Hz

  • Concentration of Inhaled Oxygen:15 % ~ 100 %

  • Multiple Working Mode:Ippv,A/C,Pcv,Simv,Spont/CPAP,Psv

  • Specification:CE, ISO

  • HS Code:90189090

Product Description

Basic Configuration

NO.namespecificationquantityunit
1Main body(With air compressor)
1PC
2Air connector of compressor
1PC
3High pressure O2 tube
1PC
4Humidifier
1PC
5Steeve
1PC
6Adult breathing tube(silica gel)
1PC
7Children breathing tube(silica gel)
1PC
8Breathing bag3L1PC
9Power line0.6M1PC
10Power line4M1PC
11FuseT1A4PCS
12FuseT2A2PCS
13FuseT6.3A2PCS
14FuseT10A2PCS
15Operation manual
1PC
16Repair card
1PC
17Certificate of Quality
1PC

 
 
Main features:
 *Two driven mode: electric and pneumatical
 *Applicable to both adults and children
 *TFT LCD display screen
 *Multiple working mode and ventilation modes such as IPPV,A/C,PCV,SIMV,SPONT/CPAP,PSV ,SIGH,MAUN
 *With alarming functions
 *With realtime compensation function
 *With air and oxygen mixer of high accuracy,stable and reliable.
 *With built-in spare power source,when outside power source goes off,spare power source starts to work
 *Compatible with air compressor
 
 Work condition:
 Gas source:O2
 Air compressor
 Rated working pressure:280kpa~600kpa
 Power source: Voltage ~220V±22V
                         Frequency: 50HZ±1HZ

Alarming and protection function:
Alarm when AC power off
Alarm when spare power voltage getting low
Alarm when there's tidal volume
Alarm when ventilation volume too high or too low
Alarm when tube pressure too high or too low
Pressure limits
Alarm when concentration of Oxygen too high or too low
Alarm when suffocation occurs
Pressure safety relief valve<125cmH2O
Main parameters
Adjusting range of parameters:
Frequency:1 bpm ~ 100 bpm(
           SIMV mode:1 bpm~ 40 bpm
           Other modes:  Adult4 bpm~ 40 bpm Children:20bpm~ 100 bpm
Tinsp(inspiratory time):0s~ 12s(Except for SIMV mode Respiratory ratio::4:1~1:8)
VT(Tidal volume) range: 0 mL ~ 2000 mL                     
                       Adult:25mL ~ 2000 mL  Children: 0 mL ~ 300 mL
PEEP: 0 cmH2O ~ 40 cmH2O 
CPAP: 0 cmH2O ~ 20 cmH2O
Continuous air flow : Adult: L/min ~ 60 L/min  
                    Children:2 L/min ~ 30 L/min
PTr(Pressure trigger):- 20cmH2O ~ 20 cmH2O
FTr:(Flow trigger)0.5 L/min ~ 30 L/min
Pc(Pressure control):5cmH2O ~ 80 cmH2O
Ps(Pressure support): 0 cmH2O ~ 80 cmH2O
Adjusting range of O2 concentration: 21 %~100 %
Holding time(Inhalation platform /TIP):  0 ~ 6s(≤50 % inspiratory time)
SIGH adjusting range:1/100 ~ 5/100
Suffocation ventilation: OFF,5 s ~ 60 s
Pressure limit range:20cmH2O ~ 100 cmH2O
Max safety pressure<12.5Kpa
 
Monitoring parameters:
Frequency:0 /min ~ 100 /min
VT(Tidal volume):0 mL ~ 2500 mL
MV(Tidal volume/min):0 L/min ~ 99 L/min
Tube pressure:0 cmH2O ~ 100 cmH2O  
Concentration of inhaled oxygen:15 % ~ 100 %
 
Graphical display 
Tube pressure-time wave line                                                            
Air flow-time wave line
Pressure volume loop