Anaesthesia Machine in Hospital (8700A)
You are here: Home » Products » Operation Room Product » Anesthesia Machine, Operating Light » Anaesthesia Machine in Hospital (8700A)
Share to:

Anaesthesia Machine in Hospital (8700A)

Quantity:
  • 8700A
  • Anaesthesia Machine
  • All People
  • Oxygen
  • All People
  • 100kg
  • +10~+40 Oc
  • 100-240V AC, 50/60Hz
  • Closed, Semi-Closed, Semi-Open
  • <=8kpa
  • CE, ISO
  • 90189070
  • Anaesthesia
  • CE, FDA
  • With LCD Display
  • Closed, Semi-Closed, Semi-Open
  • 1403mm×704mm×750mm
  • -20~+60 Oc
  • <=95%
  • 24V DC Minimum 120 Min
  • Man./Vent
  • everich
  • China
8700A Anesthesia Machine
The first Chinese anaesthesia workstation
SIMV mode with flow-trigger
Independent 10.4" screen, flexible monitoring angle
CE marked, meet clinical safety requirement of EU
Advanced electromagnetic valve ensures accurate tidal volume and compensation
Parameters monitored: P-T, F-T, V-T waveforms & P-V, F-V loops

Technical Speciication
Dimensions(H x W x D) 1403mm×704mm×750mm
Weight 100kg
Storage temperature -20~+60ºC
Workibg temperature  +10~+40ºC
Storage humidity ≤95%
Main power 100-240V AC, 50/60Hz
Battery(option) 24V DC, minimum 120 min
Working mode Closed, Semi-closed, Semi-open
Deiven mode Pneumatically driven and electronically controlled
Operating mode Man./ Vent.
Safety value ≤8kpa
Patient type Adult, pediatric
Ventilation mode  IPPV, PLV, SIMV,PS and Manual
Tidal volume 0-1600ml
Ventilator frequency 4-100bpm

Physical & Environmental Specification
Dimensions(H x W x D): 1403mm×704mm×750mm
Weight: 85kg
Storage temperature: -20~+60ºC
Workibg temperature: +10~+40ºC
Storage humidity: ≤95%

Electrical Specification:
Main power: 110-240V AC, 50/60Hz
Battery(option): 24V DC, minimum 90 min

Pneumatic Specification:
Working mode: Closed, Semi-closed, Semi-open
Deiven mode: Pneumatically driven and electronically controlled
Operating mode: Man./ Vent.
Safety value: ≤8kpa

Ventilator Specification:
Patient type: Adult, pediatric
Ventilation mode: IPPV, PLV, SIMV PS, Manual
Setting: Touch key & navigator wheel knob
Tidal volume: 0-1600ml
Ventilator frequency: 4-100bpm
I:E ratio: 2:1-1:8
Alarm: High Airway Pressure/Low Airway Pressure
             High Minute Volume/Low Minute Pressure
             High Breath Rate/Low Breath Rate
             High FiO2/Low FiO2
             O2 Supply failure
             Circle Mistake
              Power failure

PRODUCTS

QUICK LINK

CONTACT US

Tel: 0086-25-84639698,84612226
Fax: 0086-25-84613336
Zip: 210007
Address: Room 603 bld No.8 Jinlin Shanfu 118 Daguang Road Nanjing China