LCD Fetal / Maternal Monitor (BFM-700M)
You are here: Home » Products » Emergency Treatment Products » Strecher, Patient Monitor, Defibrillator » LCD Fetal / Maternal Monitor (BFM-700M)
Share to:

LCD Fetal / Maternal Monitor (BFM-700M)

Quantity:
  • BFM-700M
  • Fetal Doppler
  • Pregnant Woman
  • Surface Probe 1PCS
  • ≤30s
  • 86 Kpa106 Kpa
  • everich
  • China
  • Imaging Diagnostic Equipment
  • CE, ISO13485
  • 30 Bpm -350 Bpm
  • +5 -40
  • ≤80%
  • 0-100units
  • CE, ISO
  • 90189090

Features:
l 5.7 inches TFT LCD displays 2 x US and 1x UC data, mother's NIBP, TEMP, RR, SpO2, and ECG main parameters and monitoring trace curve etc.;
l FHR collects signal indication, alarm indication for abnormal FHR, fetal movement indication, and can freeze monitoring status;
l Can set the time limit (0-99 minutes), automatically entering dormant state if no signal input;
l Store monitoring data for 24 hours, with replay function;
l Coding keyboard adjusts all parameters setting of the unit, convenient to use;
l Adopt 832 thermal linear array printer, store the data and print rapidly; and printing width is 112mm;
l The printer parameters can be adjusted according to user needs, including printing paper speed, trace line thickness, signal sampling rate, upper and lower alarming limit, real time, and date;
l Set-up data and parameters can be automatically saved after power off;
l The monitoring data can be conveyed to exterior computer through RS-232 or USB port;
l Trolley (adjustable) for option, convenient to move and operate. 
Specification:
l US
Transducer   9 crystals, wide wave beam
Working mode: Pulsed ultrasound Doppler
Ultrasonic frequency: 1.0MHz±10%
Measuring range:    50-240 BPM
Alarm range:  Up: 55-240 BPM Adjustable continuously within range
Low: 50-235BPM Adjustable continuously within range
l TOCO
Display range: 0-100units  (non-linear error: â‰¤±10%)
l PC PORT
Edition USB 1.1 or USB 2.0; RS-232
l THERMAL RECORDER
Paper width: 112 ± 2mm effective record width: 105 ± 2mm; Paper length: 15m
Recorder density:  US:  27 BPM/ CM; UC:  40 BPM / CM
Printing speed (adjustable):  1 cm/min, 2 cm/min, 3 cm/min
l POWER and BATTERY
Battery: 16.8V Ni-MH rechargeable batteries group;  AC 220 /110 V ;  Consume power: â‰¤ 60 W
Continuous working time in static condition: â‰¥ 1 hours
l ECG and HR
Measuring range: 30 BPM -350 BPM
Cardiac electric noise level: â‰¤ 30 Î¼V
Cardiac electric frequency response:
Filtering mode: 1-25 MHz
Non-filtering mode: 0.05-100 MHz
 
Cardiac electric Input loop current: â‰¤ 0.1 Î¼A
l NIBP
Measuring range:
a) SBP: (8.034.0) kPa or (60255) mmHg
b) DBP: (4.026.0) kPa or (30195) mmHg
c) MAP: (5.328.7) kPa or (40215) mmHg
Automatic measuring interval: 3 min-99 min adjustable continuously within range
interval error: â‰¤ ±10 s
l RR
Measuring range: 0 BPM-100 BPM
l TEMP
Channels: 1
TEMP probe: surface probe 1pcs
Measuring range: 28-45
Response time: â‰¤30s
l SpO2
Measuring range: 0-99%
l PR
Measuring range: 30-250 BPM
ENVIROANMENT REQUIREMENT
Working Temperature: +5 -40   Humidity: â‰¤80%  Atmospheric pressure: 86 kPa106 kPa
 
Measuring Range Temp Probe Working Temperature Response Time Humidity Atmospheric Pressure Display Range
30 Bpm -350 Bpm Surface Probe 1PCS +5 -40 ≤30s ≤80% 86 Kpa106 Kpa 0-100units

PRODUCTS

QUICK LINK

CONTACT US

Tel: 0086-25-84639698,84612226
Fax: 0086-25-84613336
Zip: 210007