S1600 Ventilator in Hospital (model: S1600)
You are here: Home » Products » Emergency Treatment Products » Oxygen Concentrator, Ventilator and Suction » S1600 Ventilator in Hospital (model: S1600)

Product Category

Contact Person

Name: Xu Yong
Tel: 13505148410
Email1: xuyong@everichmed.com
Email2: juliet@everichmed.com

loading

Share to:
sharethis sharing button

S1600 Ventilator in Hospital (model: S1600)

Quantity:
  • S1600

  • CE, ISO13485

  • With LCD Display

  • Electric and Pneumatical

  • O2

  • ~100V~240V

  • Ippv,A/C,Pcv,Simv,Spont/CPAP

  • <125CMH2o

  • everich

  • China

  • Ventilator

  • Adult

  • Oxygen

  • TFT LCD

  • 280kpa~600kpa

  • 50/60Hz

  • 15 % ~ 100 %

  • <12.5kpa

  • CE, ISO

  • 90189090

Basic Configuration
   
NO. name specification quantity unit
1 Main body(no air compressor)
1 PC
2 High pressure O2 tube
1 PC
3 Humidifier
1 PC
4 Steeve
1 PC
5 Adult breathing tube(silica gel)
1 PC
6 Children breathing tube(silica gel)
1 PC
7 Breathing bag 3L 1 PC
8 Power line 4M 1 PC
9 Fuse T1A 4 PCS
10 Fuse T2A 2 PCS
11 Operation manual
1 PC
12 Repair card
1 PC
13 Certificate of Quality
1 PC
Main features:
 *Two driven mode: electric and pneumatical
 *Applicable to both adults and children
 *TFT LCD display screen
 *Multiple working mode and ventilation modes such as IPPV,A/C,SIMV,SPONT/CPAP,MAUN
 *With alarming functions
 *With built-in spare power source,when outside power source goes off,spare power source starts to work
 
 Work condition:
 Gas source:O2
 Rated working pressure:280kpa~600kpa
 Power source: Voltage ~100V~240V
              Frequency:50/60HZ
 
Main parameters
Adjusting range of parameters:
Frequency :1 bpm ~ 100 bpm(
           SIMV mode : 1 bpm ~ 20 bpm
           Other modes: 4 bpm ~ 100 bpm
Tinsp (inspiratory time):0s ~ 6 s ( Except for SIMV mode,Respiratory ratio: 4:1 ~ 1:8 )
VT ( Tidal volume) range: 0 mL ~ 1500 mL                     
PEEP : 0 cmH2O ~ 20 cmH2O 
CPAP : 0 cmH2O ~ 20 cmH2O
Adjusting range of O2 concentration : 45 % ~ 100 %
 
Holding time (Inhalation platform /TIP):   0 ~ 3 s( ≤ 50 % inspiratory time )
SIGH adjusting range: 1 /100 ~ 5/100
Suffocation ventilation : OFF , 5 s ~ 60 s
Pressure limit range :20cmH2O ~ 100 cmH2O
Ventilation volume under MAUA mode: >=25L/min
Max safety pressure <12.5Kpa
 
Monitoring parameters:
Frequency :0 /min ~ 100 /min
VT ( Tidal volume): 0 mL ~ 2 0 00 mL
MV( Tidal volume/min): 0 L/min ~ 99 L/min
Tube pressure: 0 cmH2O ~ 100 cmH2O  
Concentration of inhaled oxygen: 15 % ~ 100 %
 
Graphical display 
Tube pressure-time wave line                                                            
Air flow-time wave line
 
Alarming and protection function:
Alarm when AC power off
Alarm when spare power voltage getting low
Alarm when there's tidal volume
Alarm when ventilation volume too high or too low
Alarm when tube pressure too high or too low
Pressure limits
Alarm when concentration of Oxygen too high or too low
Alarm when suffocation occurs
Pressure safety relief valve<125cmH2O
Previous: 
Next: 

PRODUCTS

QUICK LINK

CONTACT US

Tel: 0086-25-84639698,84612226
Fax: 0086-25-84613336
Zip: 210007
Address: Room 603 bld No.8 Jinlin Shanfu 118 Daguang Road Nanjing China