Yp-100ab Infant Incubator (model YP-100AB)
You are here: Home » Products » Emergency Treatment Products » Infant Radiant Warmer, Incubator and Neonate Bilirubin » Yp-100ab Infant Incubator (model YP-100AB)

Product Category

Contact Person

Name: Xu Yong
Tel: 13505148410
Email1: xuyong@everichmed.com
Email2: juliet@everichmed.com

loading

Share to:
sharethis sharing button

Yp-100ab Infant Incubator (model YP-100AB)

Quantity:
  • YP-100AB

  • Electrotherapeutics

  • With LCD Display

  • 1085mm*640mm*1120mm

  • RS-232

  • 600va

  • AC220V, 50Hz

  • 0~5o C

  • CE, ISO

  • 90189090

  • Incubator

  • CE, ISO13485

  • Infant

  • 83kg

  • Natural

  • 25o C~37o C

  • Air Temperature Control 3.0o C

  • everich

  • China

Technical specification:
Power supply AC220V, 50Hz
Power input 600VA
Air Temperature control range 25º C~37º C
Sensor precision ≤ 0.3º C
Changing of temperature ≤ 0.5º C
Temperature rising time ≤ 30min
Noise level ≤ 55dB(A)
Inclination of bassinet 0~5º C
Package size 1085mm×640mm×1120mm   
Net weight 83kg
Over-temp alarm: When the temperature ≤ 38º C
Upper Deviation alarm Air temperature control 3.0º C
Lower Deviation alarm Air temperature control -3.0º C

Power supply: AC220V, 50Hz
Power input: 600VA
Air Temperature control range: 25º C~37º C
Sensor precision: ≤ 0.3º C
Changing of temperature: ≤ 0.5º C
Temperature rising time: ≤ 30min
Noise level: ≤ 55dB(A)
Inclination of bassinet: 0~5º C

Alarming:
Audible and visible alarm indication, and it can indicate the real temperature and cut off the power supply of heater (except for the low deviation alarm), meanwhile, the skin temperature indication window can indicate the alarm code. For the alarm 1-6, the relevant light is on, and for the alarm 7, all alarming lights are on; All alarm sound can be cancelled except for the power failure alarm and the system alarm.
Over-temp alarm: When the temperature ≤ 38º C;
Upper Deviation alarm: Air temperature control 3.0º C
Lower Deviation alarm: Air temperature control -3.0º C
Sensor alarm: When the sensor is disconnected, open circuit, short circuit or put on the wrong place;
Fan alarm: When the fan is blocked, speed ≤ 1000rpm or stop working;
Power failure alarm: When there is no power or the power cord is disconnected.
System alarm: When there is E2ROM malfunction inside of temperature controller.

Air mode control,set temperature and air temperature are displayed separately;
Natural air flow humidity;
Failure alarm indication;
RS-232 connector.
 YP-100AB is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90 (with blue fluorescent lamps)
YP-100AB is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90L (with LED bulb) as optional.

Package size:1085mm×640mm×1120mm   
Net weight: 83Kg

Previous: 
Next: 

PRODUCTS

QUICK LINK

CONTACT US

Tel: 0086-25-84639698,84612226
Fax: 0086-25-84613336
Zip: 210007
Address: Room 603 bld No.8 Jinlin Shanfu 118 Daguang Road Nanjing China